Situation:       

A private septage processing facility in New England consistently had a problem complying with its NPDES groundwater discharge permit for nitrogen. The facility receives around 475,000 litres per day of high strength septage but allows up to 40 per cent of the accepted liquids to be fat, oil and grease (FOG) from commercial grease traps.

Further, a large portion of the septage is from porto-potty haulers, which contains highly concentrated levels of ammonia nitrogen from urine.

The facility was designed with two in-ground receiving tanks, a plate and frame press and two in-ground EQ tanks prior to the in-plant processes which include clarification, aerobic RBCs and anoxic RBCs (rotating biological contactors).

In each of the in-ground EQ tanks were propeller-type mixers which would mix the contents but did nothing to “condition” the liquids. Eventually, the shafts broke from exposure to the low acidic pH condition and they were not replaced. This low pH and absence of DO condition directly impacted the viability of the biomass on the RBCs, and viability wavered depending on the strength of the influent wastestream that changed daily.

Sulfide odour complaints:

Venturi Aeration was able to review the process and it became very evident that the two in-ground EQ tanks were allowing the supernatant off the plate and frame press to go totally anaerobic.

The desired dilution from the returned activated sludge and a portion of the treated water to the EQ tanks prior to the RBCs was also going anaerobic.

These EQ tanks were a major source of hydrogen sulfide (H2S) odours that were being released into the surrounding neighborhood and a source of numerous complaints to the DEP.

Solution:             

To address the issue of odour complaints from neighbours, two venturi aerators were added to the outside, in-ground EQ tanks.  

The oxygen supplied by the venturi aerators from ambient air would oxidize the sulfides into sulfates eliminating odours. One Gorman-Rupp pump (T-4 modified with an anti-clog bar assembly) supplied septage in one EQ tank to a split flow into two venturi aerator units, one in each of the two in-ground tanks. Not only are the units very effective in controlling H2S odours but several other benefits were achieved that were not anticipated.

Additional process benefits and changes:

First, the venturi aerators were able to convert the low pH anaerobic liquids from 5.9 to 7.2 within 30 minutes of starting the system. This also imparts high levels of residual dissolved oxygen (DO) converting the liquids into aerobic conditions.  

When aerobic activity begins, the natural microorganisms off gas carbon dioxide as a byproduct of their digestive processes. As CO2 concentrations increase, pH decreases. But a pH of >6.85 is required for nitrification to begin. Inasmuch as the venturi aerator also strips a significant portion of the carbon dioxide, a highly pH level is achieved. One formula for reviewing this non-chemical pH adjustment is:

                           pH  = 6.35  + log(alkalinity/carbon dioxide)

By stripping the carbon dioxide in the aerobic wastewater, a logarithmic increase in pH can occur. And as dissolved oxygen levels increase with repeated recirculation, the ORP is changed from negative (-) mV values which are ideal for anaerobic conditions to positive (+) ORP values necessary for aerobic digestion.

Nitrogen reduction:

By adding additional dissolved oxygen while raising the pH, nitrogenous compounds are converted from ammonia nitrogen into nitrates metabolically. This is accomplished by providing a ratio of 3.5 pounds of DO per one pound of nitrogen compounds.

While a certain amount of DO is consumed for BOD reduction (1# BOD to 1.5 # DO), excess amounts of DO aid in reducing nitrogen compounds making them more metabolically bioavailable for Nitrobacters.  

An initial review of the CFUs (colony forming units) in the tank showed there were insufficient Nitrobacter colonies. To remedy this a BactivatorÒ unit was added to continually dose live cultured Nitrobacters along with colonies of grease eaters into the process return liquids and then returned to the EQ tank.

This ensures that as conditioned liquids flow from the EQ tanks to the RBCs that there will be sufficient CFUs of both grease eaters and Nitrobacters to degrade the organic materials.

TSS and enhanced settling:

One of the benefits of a highly aerated liquid in the EQ tank is the enhanced settling of the suspended solids (TS) in the clarifier in front of the RBC units. This enhanced settling occurs because of several reasons.

First, as the organic materials are picked up by the pump and pumped into the venturi aerator they are accelerated. Then as they go through the venturi aerator they exit the venturi’s internal nozzle where there is a rapid decrease in pressure (Dp = 14 psi) which causes the organic materials to break apart releasing imbedded gases which are oxidised, eg hydrogen sulfide, imbedded gases increase buoyancy inhibiting settling.  

As dissolved oxygen saturates the liquid the heavier particles settle to the bottom of the tank because of the change in specific gravity in the liquid itself. By releasing imbedded gases and removing a significant portion of these organic solids, the RBC can operate according to original design organic loadings. If not released, these gases can accumulate and cause a low pH condition in the RBC.

Sometimes covered RBCs need to have an exhaust fan installed to extract the buildup of carbon dioxide under the cover in the headspace of the covered tank (Ref: Wayland-Sudbury WWTP 1992). Carbon dioxide has a vapor density >1 and it can accumulate in the headspace under the cover. Frequently, this is overlooked when diagnosing RBC performance issues.

BOD reduction:

By adding dissolved oxygen in large quantities, BOD reduction can occur in the pre-aeration EQ tanks. By reducing the organic loadings to original design parameters the RBCs work more efficiently. Having a residual DO means the microorganisms receive a wastestream that has been conditioned to optimise RBC performance.

Summary:

By adding venturi aerators to the two in-ground EQ tanks prior to the RBCs, additional dissolved oxygen is added to condition the septage to enhance BOD reduction, TSS settling and nitrogen reduction.

The RBCs work more efficiently and this facility is now consistently able to comply with its NPDES permit for nitrogen levels. Adding the Bactivator ensures a continuous supply of viable colony forming units of Nitrobacters and grease eaters to the RBCs in case there was sloughing for some reason off the stator plates on the RBCs.  

As a result of NPDES permit compliance, the facility is looking to expand it daily permit to 750,000 litres of septage and will add additional venturi aerator units in the new EQ tank to handle this increase in capacity throughput.

More on Venturi Aerator.

This partner content is brought to you by Hydro Innovations. For more information, call 02 9898 1800, email [email protected], or visit https://www.hydroinnovations.com.au/pump-applications/venturi-aerator/.

Find Engineering Related Companies In The Pump Industry Capability Guide



Related articles
0 Comments

©2024 Pump Industry. All rights reserved

CONTACT US

We're not around right now. But you can send us an email and we'll get back to you, asap.

Sending

Log in with your credentials

or    

Forgot your details?

Create Account